17mm Submersible Level Transmitter
φ17mm
0m~10m…200mH2O
Measurement Accuracy: ±0.5%FS
New Product Change Notice (PCN) effective Jan 1, 2025. MICROSENSOR appreciate your understanding.
LR725L
Used For
Measurement of Liquid, Slurry, and Solids on Industrial Sites
Leave a MessageThe LR725L Ultrasonic Level Meter adopts the wireless transmission principle without touching the measurement medium. The ultrasonic level transmitter uses the speed of sound waves to calculate liquid level. The high and stable measurement accuracy is owned by the constant speed of sound wave transmission. LR725L can measure liquid levels up to 50m. The products adapt to different industrial application scenarios' requirements, including corrosive and high-temperature liquids. MicroSensor LR725L non-contact liquid level transmitter is with simple installation and easy maintenance. It is widely used in industrial field measurement of liquids and slurries.
Features
• Contactless Level Meter
• Highly efficient and low-cost measuring equipment
• Wide measuring range: 1m~50m
• IP68 Probe protection level
Specification
• Level range: 5m, 10m, 15m, 20m, 30m, 40m, 50m
• Accuracy: ±0.5%FS~±1.0%FS
• Resolution: 3mm or ±0.1% (max. value is valid)
• Display: English LCD display
• Analog output: 4mA~20mA DC (510Ω load)
• Relay output: single channel is 2 groups; dual channel is 4 groups AC 250V/8A or DC 30V/5A state programmable (optional)
• Power supply: 220V AC (±15%, default) / 24V DC 120mA (optional) / 12V DC, 9V DC, battery powered (customized)
• Ambient temperature: display instrument -20℃ ~60℃, probe -20℃ ~80℃
• Communication interface: RS485 RS232 optional (manufacturer’s protocol)
• Protection: Indicator IP65 (integrated type)
Converter IP65, probe IP68 (separated type)
• Probe cable: up to 100m without electromagnetic interference, 10m as standard (separated type only)
• Probe installation: according to range and probe selection
Image:
The LR725L Ultrasonic Level Meter adopts the wireless transmission principle without touching the measurement medium. The ultrasonic level transmitter uses the speed of sound waves to calculate liquid level. The high and stable measurement accuracy is owned by the constant speed of sound wave transmission. LR725L can measure liquid levels up to 50m. The products adapt to different industrial application scenarios' requirements, including corrosive and high-temperature liquids. MicroSensor LR725L non-contact liquid level transmitter is with simple installation and easy maintenance. It is widely used in industrial field measurement of liquids and slurries.
Features
• Contactless Level Meter
• Highly efficient and low-cost measuring equipment
• Wide measuring range: 1m~50m
• IP68 Probe protection level
Specification
• Level range: 5m, 10m, 15m, 20m, 30m, 40m, 50m
• Accuracy: ±0.5%FS~±1.0%FS
• Resolution: 3mm or ±0.1% (max. value is valid)
• Display: English LCD display
• Analog output: 4mA~20mA DC (510Ω load)
• Relay output: single channel is 2 groups; dual channel is 4 groups AC 250V/8A or DC 30V/5A state programmable (optional)
• Power supply: 220V AC (±15%, default) / 24V DC 120mA (optional) / 12V DC, 9V DC, battery powered (customized)
• Ambient temperature: display instrument -20℃ ~60℃, probe -20℃ ~80℃
• Communication interface: RS485 RS232 optional (manufacturer’s protocol)
• Protection: Indicator IP65 (integrated type)
Converter IP65, probe IP68 (separated type)
• Probe cable: up to 100m without electromagnetic interference, 10m as standard (separated type only)
• Probe installation: according to range and probe selection


Φ26mm
0m~1m…200m H2O
Accuracy: ±0.25%FS, ±0.5%FS, ±1%FS
DNV approved for installation on all vessels
ATEX Certificated

Contactless Level Measurement
Measuring range: 0m~70m
Measured media: Solid, Liquid

Level measurement: 0mH2O~2mH2O…200mH2O
Pressure measurement: 0mabr~200mabr...350bar
Outputs: 4mA~20mA, 1V~5V, 0.5V~4.5V...RS485-Modbus, etc.
CCS, ABS, DNV approved for ship use

Pressure, level, and flow measurements at the rainwater outlet ensure stable drainage. Monitoring instruments help detection and early warning of pipe burst incidents in time.
more info...
By monitoring the sewage flow, pipeline pressure and reservoir level, the efficiency of sewage treatment plant can be improved. At the same time, it can also facilitate operation and management, and achieve energy saving and automation control.
more info...
When the malt juice cools to the appropriate temperature, adding yeast initiates the fermentation process. During this process, yeast converts maltose dissolved in the malt juice into carbon dioxide and alcohol. To ensure a smooth fermentation process, it is necessary to measure the temperature and liquid level of the fermentation tank, as well as the carbon dioxide in the recovery pipe and the pressure in the yeast pipe.
more info...
Install instruments like electromagnetic flowmeters, temperature/pressure transmitters, flow controllers in the pressure pumps, water injection pipelines, and water injection wells to monitor the water injection volume, pressure, and level changes in real time so that the pressure and volume of the well-injected water can be controlled.
more info...